IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V Single conductor Type T/N distribution cables

Construction

Conductor:

Stranded copper conductor tin or alloy coated where necessary for the application , conductor per ASTM or IEC

60228.

Separator tape: optional

Insulation: Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE

as option.

Shielding: optional

Jacket:

Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO

jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath:

Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO

sheath as option (optional except for tinned copper braid armoured cables).

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.3—Typical dimensions and weights; single-, two-, three-, and four-conductor 600/1000 V; Type T/N

distribution cables


Number of conductors
AWG /kcmil Unarmored Armored Armored and sheathed
Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

1

14 0.21 31 0.27 44 0.37 74

1

12 0.23 41 0.29 54 0.39 87

1

10 0.26 58 0.32 74 0.42 110

1

8 0.32 90 0.38 108 0.48 149

1

6 0.34 123 0.4 141 0.5 184

1

4 0.42 188 0.48 212 0.61 280

1

1 0.58 364 0.64 395 0.76 476

1

1/0 0.63 440 0.69 473 0.81 560

1

2/0 0.67 536 0.73 571 0.89 696

1

3/0 0.73 653 0.79 690 0.95 824

1

4/0 0.79 801 0.85 841 1.01 985

1

250 0.89 977 0.95 1022 1.12 1192

1

300 0.96 1163 1.02 1213 1.19 1394

1

350 1 1315 1.06 1365 1.23 1553

1

400 1.05 1505 1.11 1558 1.28 1753

1

500 1.13 1811 1.19 1867 1.36 2076

1

600 1.24 2225 1.3 2290 1.47 2517

1

750 1.34 2686 1.4 2757 1.57 3001

1

1000 1.49 3530 1.55 3608 1.78 3978

NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.